MSG® TURBO-AIR® COOLED 2000 Centrifugal Air Compressor

The MSG TURBO-AIR COOLED 2000 is great for almost any location and environment. The air-cooled design eliminates installation restrictions and utility costs associated with water-cooled units by eliminating the costs of pumping and treating water, as well as the maintenance of the water supply system.

FOR MORE INFORMATION

If you need more information or would like a quote, we are here to help.

The MSG TURBO-AIR COOLED 2000 is great for almost any location and environment. The air-cooled design eliminates installation restrictions and utility costs associated with water-cooled units by eliminating the costs of pumping and treating water, as well as the maintenance of the water supply system.

Description

RELIABLE CENTRIFUGAL COMPRESSOR – NOW AVAILABLE WITH AIR COOLING

The MSG TURBO-AIR COOLED 2000 centrifugal compressor is designed for applications where there is a limited supply or lack of cooling water.

The MSG TURBO-AIR COOLED compressor allows more industries around the world to take full advantage of our state-of-the-art centrifugal compressor design.

Comparison of operational economics: air and water cooling

 

CERTIFIED ISO CLASS 0

The MSG TURBO-AIR range of centrifugal compressors has been developed for the production of oil-free air for more than 60 years. This certificate officially confirms the ability of our compressors to produce 100% oil-free air, providing our customers with increased quality assurance.

 

ISO 8573-1 certified oil-free air

  • Prevents oil contamination of your system.
  • Limits the possibility of compressed air pipelines catching fire caused by oil removal.
  • Eliminates costly waste management problems associated with oil-saturated condensate.
  • Eliminates costs and associated maintenance requirements for oil-removing filters, as oil does not enter the compressed air flow in the compressor.

Easy installation

  • The real possibility of unloading helps to take advantage of energy saving opportunities.
  • Increased uptime compared to alternative technologies results in lower operating costs over the life cycle.
  • Reduced the number of external connections
  • Compact design reduces footprint
  • Complies with OSHA noise level requirements without sound insulation casing.

Low cost of operation

  • The real possibility of unloading helps to take advantage of energy saving opportunities.
  • Increased uptime compared to alternative technologies results in lower operating costs over the life cycle.
  • Excellent partial load efficiency for any workload
  • There are no sliding or rubbing parts during the compression process,

Easy operation

  • The MAESTRO ™ universal control panel is equipped with a built-in web server that allows you to monitor the compressor using a local intranet / group>.
  • Significant annual savings in operating costs due to more precise control.
  • Easy to use, automatic operation.

Easy maintenance

  • Compression elements do not wear out and do not require periodic replacement.
  • No oil separation filters that require cleaning or replacement.
  • Available gearbox with horizontal connector for quick inspection.
  • The intercooler and intercooler kits can be easily removed for inspection and cleaning.
  • An intercooler and a water-in-tube intercooler provide easy mechanical cleaning.
  • Maintenance-free dry coupling

High reliability

  • Axial loads perceived at low speed
  • Contactless air and oil seals
  • Stainless steel compression elements
  • Conservative, high-quality gear design.
  • Gear bearing design with extended service life
  • Centrifugal compressors are proven to have a long average time to failure (MTBF), and independent studies have shown the industry's best operational availability of 99.7%.

MSG TURBO-AIR COOLED 2000 centrifugal compressors Three-stage compressor diagram

  1. Oil cooler:air-cooled heat exchanger for the lubrication system.
  2. Aftercooler:air-cooled heat exchanger for stage 3 forced air.
  3. 2nd stage intercooler:air-cooled heat exchanger for stage 2 forced air.
  4. 1st stage intercooler:air-cooled heat exchanger for stage 1 forced air.
  5. Fan and cooling fan:Fan and chamber to facilitate air-cooled heat transfer.
  6. Intake filter:removes airborne particles before the 1st compression stage.
  7. 3rd stage of compression:the last stage of compression to achieve the set pressure.
  8. 2nd stage of compression:intermediate compression stage before the final compression stage.
  9. 1st compression stage:the initial stage of atmospheric air compression.
  10. Control Center:single-point electrical connection for the MAESTRO universal control panel, drive motor starter and auxiliary equipment.
  11. Soundproof enclosure:The enclosure provides quiet operation at a noise level of 85 dBA.
  12. Compressor release:Discharge from the final compression stage to the aftercooler and subsequent equipment.

 

SUBMIT YOUR APPLICATION

Leave us a request and our managers will contact you